Product model
|
JWE-D120K-1000V-OHB
|
JWE-D150K-1000V-OHB
|
JWE-D180K-1000V-OHB
|
Installation method
|
Console mode
|
Console mode
|
Console mode
|
Rated power
|
120 kW
|
150 kW
|
180 kW
|
Technical indicators
|
AC input voltage: three-phase five-wire AC 380V ± 15%
|
Power factor correction is integrated inside the charger to minimize harmonic pollution to the power grid
|
DC output voltage:200-1000V
|
Maximum output current of single gun: 250A
|
Power factor: above half load, > 0.98; Load 20% - 50%, > 0.95
|
System efficiency: Full load > 95%; More than half a load > 93%;
|
Using high-frequency zero voltage soft switching technology, the reliability and efficiency of operation are much higher than those of hard switching circuits.
|
Steady current accuracy: <± 1%
|
Voltage stabilization accuracy: < ± 0.5%
|
Output voltage ripple coefficient: < ± 1%
|
Harmonic current:<5%
|
Standby power consumption: ≤ 100W
|
Zero power consumption in standby state of primary circuit
|
Protection grade: IP54
|
Protection features: multiple protection functions such as input undervoltage, input overvoltage, output short circuit, output overvoltage, battery reverse connection, insulation detection, communication failure, etc.
|